Rain + soil + flood
See current environmental pressure, confidence, trend and the public layers behind it — without pretending the result is a septic diagnosis.
U.S. property planning · free browser tool
Turn real measurements into a pre-permit decision pack: check CDC well-separation guidance, compare tank and drainfield rules from your state’s official setback table, see your tightest known clearance, and leave with the exact questions still worth asking.
Property screen
Sample values are prefilled so you can see how the tool works. Replace them with field measurements or a survey/site plan. Distances are horizontal planning measurements in feet.
Permit-readiness checklist
Tick what you already know. This checklist is saved only in your browser.
Official rules, side by side
Statewide minimums from each state’s onsite wastewater rule, with the drainfield and the septic tank kept separate. Choose your state in the checker above to load the full set of minimums into your screen.
Minimum drainfield distance (tank where no drainfield value) to the well, in feet. 32 states with a cited statewide rule; tap a state for its full rules.
| State | Tank → well | Drainfield → well | Tank → house | Drainfield → house |
|---|---|---|---|---|
| Arizona | 100 | 100 | 10 | 10 |
| Arkansas | 100 | 100 | 10 | 10 |
| Colorado | 50 | 100 | 5 | 10 |
| Florida | 75 | 75 | 5 | 5 |
| Georgia | verify | 100 | verify | 10 |
| Indiana | 50 | 50 | 10 | 10 |
| Iowa | 50 | 100 | 10 | 10 |
| Kansas | 50 | 50 | 10 | 20 |
| Kentucky | 50 | 70 | 10 | 10 |
| Maine | 50 | 100 | 8 | 20 |
| Massachusetts | 50 | 100 | 10 | 20 |
| Minnesota | 50 | 50 | 10 | 20 |
| Mississippi | 50 | 100 | 5 | 5 |
| Missouri | 50 | 100 | 5 | 15 |
| Montana | verify | 100 | verify | 10 |
| Nebraska | 50 | 100 | 10 | 10 |
| Nevada | 100 | verify | 10 | 10 |
| New Jersey | 50 | 100 | 10 | 25 |
| New Mexico | 50 | 100 | 5 | 8 |
| New York | 50 | 100 | 10 | 20 |
| North Carolina | 50 | 50 | 5 | 5 |
| Ohio | 50 | 50 | 10 | 10 |
| Oregon | 50 | 100 | 5 | 10 |
| Pennsylvania | 50 | 100 | 10 | 10 |
| South Carolina | 75 | 75 | 5 | 5 |
| Tennessee | 50 | 50 | 5 | 10 |
| Texas | 50 | 100 | 5 | 5 |
| Utah | 50 | 100 | 5 | 5 |
| Washington | 50 | 100 | 5 | 10 |
| West Virginia | 50 | 100 | 10 | 10 |
| Wisconsin | 25 | 50 | 5 | 10 |
| Wyoming | 50 | 100 | 5 | 10 |
Property-line and surface-water distances, footnotes and the exact citation for every state are on the full table. Counties can be stricter — treat these as floors.
Compare all setbacks by stateWhy this screen is different
EPA states that individual onsite systems are regulated by states, tribes and local governments. A single universal setback table would be misleading.
CDC advises placing a private well at least 50 feet from septic tanks and septic leach fields. We screen that explicitly, while still telling you to check stricter local rules.
Understand the 50-ft well check →If you know your county’s minimum to a property line, foundation, waterbody or traffic area, enter it. The tool compares it without pretending that number applies nationwide.
Plan the other setbacks →Missing rule? The result says “verify” and points you toward the state/local authority. That is more useful than a confident but wrong pass/fail.
Find the regulator path →Useful before money changes hands
Use a survey or listing map to spot whether the well, house, drainfield and reserve area are competing for the same space.
Build the site-plan checklist →New structures can consume setback or repair-area space even when the existing septic system works today.
Check the site-change risks →Turn inspection notes and measured distances into specific questions for the seller, inspector and local permitting office.
Check a written septic inspection report →Already have an inspection report?
Paste the report into Dakiv’s private in-browser checker. It maps which inspection topics are mentioned, flags what was not detected in the text and builds follow-up questions without uploading or storing the report.
The checker separates coverage from condition: “mentioned” does not mean “passed,” and “not detected” can mean the topic is in a photo, attachment or differently worded section.
Important limit
Soil treatment capacity, vertical separation to groundwater or limiting layers, slope, system technology, reserve area, local design flow and permit history can change what is allowed. Use Dakiv to organize the facts, then use the official permit process to decide the site.
Contact the local permitting authority for site-specific septic requirements and required setbacks.
Read EPA septic FAQs ↗